Innovative solutions for electrochemical research
IviumStat2.h

IviumStat2.h

Choose configuration:

Scan range: ±5A/±10V

FRA/EIS: 10µHz to 8MHz

Sampling rate up to 2MHz

You can buy this product from your local reseller:

Ivium Technologies B.V.

Request information

Product description

Wide application range: 

The IviumStat2.h is well suited for applications requiring a wide dynamic range, such as battery testing, corrosion measurements and electrochemical research applications. It has a high power of ±5A and low current ranges, down to 1pA full scale.

Complete solution: 

The IviumStat2.h offers a complete package, all the standard electrochemical techniques are included. The IviumStat2.h also has an integrated  high-performance Frequency Response Analyser for EIS measurements from 10µHz to 8MHz. All measurement and dataprocessing software is included (for Windows based PCs).

Safety:

The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Automation: 

Multiple analog and digital inputs & outputs are available on the peripheral port for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.

Expandability:

The IviumStat2.h can be expanded with a wide variety of options and modules, including a Bipotentiostat, True Linear Scan generator, various power boosters and multiplexers.

Hardware:

  • Automatic current range selection: 1pA to 10A/1mV to 10V
  • Automatic variable noise filter and potentiostat/galvanostat stability settings
  • Simultaneous acquisition of current/potential and peripheral analog signals
  • Real time data display up to 3,000 pnts/s. Acquisition up to 2,000,000 pnts/s (1,000,000 stored in instrument memory)
  • Applicable scanrates: 1µV/s to 10,000V/s
  • Minimum interval time: 0.5µs (0.125µs resolution)
  • Result optimisation by automated tuned filters, gain amplifiers and DC-subtraction
  • User selectable floating operation

Software:

The IviumStat2.h is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, peripheral instrument control, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included as standard with each instrument.

Read the full description

Specifications

System performance
Current compliance
±5A
Maximum compliance voltage
±10V
Maximum applied voltage
±10V below 1A, and ±8V up to 5A
Electrode connections
4; WE, CE, RE, S (and GND) with 4mm banana plugs
Potentiostat bandwidth
8MHz
Stability settings
High Speed, Standard and High Stability
Programmable response filter
1MHz, 100kHz, 10kHz, 1kHz, 10Hz
Signal acquisition
Dual channel 24bit ADC, 2,000,000 samples/s (max. 1M datapoints)
Potentiostat
Applied potential range
±10V, 0.02mV res. (20bit)
Applied potential accuracy
0.2% of value or 1mV
Current ranges
±1pA to ±10A
Measured current resolution
0.00005% of current range, minimum 0.5zA
WE bias current
20fA
Measured current accuracy
20fA + 0.025% of FSR
Galvanostat
Applied current resolution
0.002% of applied current range
Applied current accuracy
0.2% of value or 0.1% of current range
Galvanostatic current ranges
±10pA to ±10A
Potential ranges
±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
Measured potential resolution
0.00001% of potential range, minimum 0.15nV
Measured potential accuracy
0.2% of value or 1mV
Impedance Analyser
Frequency range
10µHz to 8MHz
Amplitude
0.02mV to 2.0V, or 0.03% to 100% of current range
DC offset
16bit DC offset subtraction and 2 DC-decoupling filters
Dynamic range
0.05nV to 10V, and 0.5zA to 5A
Electrometer
Input impedance
>1000Gohm //<8pF
Input bias current
<10pA
Bandwidth
>16MHz
Special functions
Ohmic drop compensation
2V/current range
Floating operation
User selectable
Peripheral connections
Analog in/out
2/1 (±10V; inputs 24bit resolution, output 16bit resolution; bandwidth 40kHz)
Digital input/output
1 input (0-5V) / 3 output (0-3.3V)
I-out/E-out
Analog monitor for cell current and potential
AC-in
±4V
AC-out
±0.5V sinewave 10µHz-8MHz with variable attenuation
Channel-X input, Channel-Y input
±4V: to record impedance from peripheral devices
Environment
Power requirements
100-240V, 47-63Hz, 150VA
Interfacing
USB
Size (w x d x h)
26 x 33 x 12cm
Weight
4.2kg
PC requirements
Windows 8/10/11, with free USB port
Specifications subject to change, Ivium Technologies ©2024

Product gallery

IviumStat2.h blank screen

Model comparison

IviumStat2.h
IviumStat.XRe
System performance
Current compliance
±5A
±2A
Maximum compliance voltage
±10V
±50V
Maximum applied voltage
±10V below 1A, and ±8V up to 5A
±50V
Signal acquisition
Dual channel 24bit ADC, 2,000,000 samples/s (max. 1M datapoints)
Dual channel 24bit ADC, 100,000 samples/s
Potentiostat
Applied potential range
±10V, 0.02mV res. (20bit)
±10V/±50V with 0.02mV/0.1mV res. (20bit)
Measured current resolution
0.00005% of current range, minimum 0.5zA
0.00001% of current range, minimum 0.6aA
WE bias current
20fA
-
Measured current accuracy
20fA + 0.025% of FSR
10pA + 0.025% of FSR
Galvanostat
Applied current resolution
0.002% of applied current range
0.00013% of applied current range
Applied current accuracy
0.2% of value or 0.1% of current range
0.2%
Galvanostatic current ranges
±10pA to ±10A
±100pA to ±10A
Potential ranges
±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV,±1V, ±4V, ±10V, ±50V
Impedance Analyser
Amplitude
0.02mV to 2.0V, or 0.03% to 100% of current range
0.015mV to 1.0V, or 0.03% to 100% of current range
Dynamic range
0.05nV to 10V, and 0.5zA to 5A
0.05nV to 50V and 0.2aA to 2A
Special functions
Floating operation
User selectable
-
Peripheral connections
Analog in/out
2/1 (±10V; inputs 24bit resolution, output 16bit resolution; bandwidth 40kHz)
8/2 (0 to +4V, 16bit resolution)
Digital input/output
1 input (0-5V) / 3 output (0-3.3V)
2 input (0-5V) / 3 output (0-3.3V)
Environment
Power requirements
100-240V, 47-63Hz, 150VA
100-240V, 45-63Hz, 300VA
Weight
4.2kg
5.3kg

Need help?

Our experts are ready to answer your questions.

Information request

Postal address

  • Ivium Technologies B.V.
  • De Zaale 11
  • 5612 AJ Eindhoven
  • The Netherlands

Visiting address

  • Ivium Technologies B.V.
  • De Lismortel 31
  • 5612 AR Eindhoven
  • The Netherlands

Contact

  • T +31 40 2390600
  • F
  • E info@ivium.com
©2024 Ivium Technologies B.V.

Sitemap